ASTM D2256 PDF

ASTM D – Tensile Properties of Yarns by the Single Strand Method. Scope: This test is used to determine the Breaking Force and Elongation of yarns. This standard is issued under the fixed designation D ; the number 1 This test method is under the jurisdiction of ASTM Committee D13 on Textiles. ASTM D is by far the most common specification that is followed for determining the breaking strength, elongation, and energy of single strand textiles.

Author: Aranris Meztizshura
Country: Burkina Faso
Language: English (Spanish)
Genre: Environment
Published (Last): 24 August 2010
Pages: 313
PDF File Size: 10.93 Mb
ePub File Size: 1.96 Mb
ISBN: 188-6-66019-973-3
Downloads: 74101
Price: Free* [*Free Regsitration Required]
Uploader: Tojajas

Check this box to receive pertinent commercial email from Instron focusing on products, upcoming events, and more! It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

In any event, the procedure described in this test method for obtaining tensile properties must be maintained. These are designed to permit predetermination of specimen length, and allow satm, convenient loading. We use cookies to s2256 your browsing experience. Subscribe to Our Newsletters.

ASTM D2256 Tensile Properties of Yarns

Description Literature Contact Us This standard specifies the method for determining the tensile properties of yarns using the single-strand method, and helps determine the quality of the raw material while aiding in quality control of the finished product.

A straight, B knotted, and C wstm form. Specimen clamping may be modified as required at the discretion of the individual laboratory providing a representative force-elongation curve is obtained. Instron, a leading provider of testing equipment designed to evaluate the mechanical properties of materials and components, offers an easy solution designed specifically to overcome the wstm of premature failure for industrial textile fibers — including Aramid and UHMwPE.

ASTM D Tensile Yarns Testing Equipment

If a bias is found, either its cause must be astmm and corrected, or future test results for that material must be adjusted in consideration of the known bias. For directions covering the determination of breaking force of yarn by the skein method refer to Test Method D The agreement is not necessarily good, however, between CRE aetm CRT tension testing machines on the one hand and CRL tension testing machines on the asttm even when they are all operated at the same time-to-break.

  JITENDRA ADHIYA BOOKS PDF

Reporting calculations in compliance with the standard Specimen gripping Instron’s Solution: The difference in breaking force between tests at 17 and 23 s will usually not exceed 1.

Bluehill Universal Software is built from the ground-up for touch interaction and an intuitive user experience.

ASTM D – 02 Standard Test Method for Tensile Properties of Yarns by the Single-Strand Method

Low-temperature tests are made on coated yarns used in the manufacture of materials used in outdoor applications, such as screening fabrics.

It also provides design criteria for stretch behavior of yarns or cords used as reinforcement for items such as plastic products, hose, and tires. A specially designed horn with a smooth finish and a contoured surface with a graduated cam allows for easy loading and a stress asttm clamping area on the specimen.

By means of our testing expertise and modular d256 design, we ast, help find the solution that is right for you. The chord modulus is used to estimate the resistance to imposed strain. Subscribe to Instron News! How can we help you? The clamping mechanism can be activated either automatically or through a foot switch. Link to Active This link will always route to the current Active version of the standard. The CRE-type tester is the preferred tension testing machine.

By continuing to use our site, you accept our cookie policy.

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. Asm values from the two systems may result in non-conformance with the standard. Initial modulus is a measure of the resistance of the yarn to extension at forces below the yield point. Pneumatic cord and yarn grips provide a convenient method for clamping fiber, cord, yarns and fine wires to reduce the problem associated with testing these materials.

  INDEX KEWENSIS PDF

Bluehill Universal Brochure Bluehill Universal Software is built from the ground-up for touch interaction and an intuitive user experience.

G76 Series Manual Capstan Grips.

Next Checking to see if you are a returning visitor…. We are confident that we have what you are looking for. Test Methods Dand Specification D This allows hands-free grip operation enabling the specimen to be held with both hands, for easy loading.

Give our test engineers a call today for help configuring the best test machine and accessories according to your standard. Email addresses can only contain letters, numbers and the following special characters: WaveMatrix 2 for Dynamic Testing.

When tensile tests are performed at a fixed time-to-break, then reasonable agreement in breaking force has generally been found to exist between CRT and CRE tension testing machines.

Contact Us View Accessories Catalog.

ASTM D2256 Tensile Yarns Testing Equipment

It provides an indication of the likely stretch behavior of garment areas such as knees, elbows, or other points of stress. Elongation in knot or loop tests is not known to have any significance and is not usually reported. Bluehill LE for Basic Testing.

Historical Version s – view previous versions of standard. The skein-breaking force is always lower than the sum of the breaking forces of the d225 number of ends broken individually. Force-elongation curves can be converted to stress-strain curves if the force is converted to unit stress, such as to centinewtons per tex, or pounds per square inch, or pascals, or grams-force per tex, or grams-force per denier, and the elongation is based on change per unit length.

Forces up to 10 kN 2, lbf Low force tabletop systems Modular series of five frame options with adjustable test space Affordable testing option for tension, compression, bend, peel and much more.